Technical Data: Sofar 70000TL-G2
Input (DC)
Max. PV array power 93100 Wp
Max. input voltage 1000 V
MPP voltage range 250 V to 950 V
Rated input voltage 600 V
Min. input voltage / initial input voltage 350 V
Max. input current per string 90 A
Number of

AED8,040.00
Availability: In stock
SKU
SFRINV000028

Delivery Time:

2 to 4 weeks

Technical Data: Sofar 70000TL-G2
Input (DC)
Max. PV array power 93100 Wp
Max. input voltage 1000 V
MPP voltage range 250 V to 950 V
Rated input voltage 600 V
Min. input voltage / initial input voltage 350 V
Max. input current per string 90 A
Number of independent MPP inputs / strings per MPP input 3 / 4-4-4

Output (AC)
Rated power (at 230/400 V, 50 Hz) 70000 W
Max. apparent power AC 70000 VA
Nominal AC voltage 220 V / 380 V,230 / 400 V
Nominal AC voltage range 310 V to 480 V
AC grid frequency / range 50 Hz, 60 Hz / −5 Hz to +5 Hz

More Information
Application

Residential 

Technical Specification

Technical Data: Sofar 70000TL-G2
Input (DC)
Max. PV array power 93100 Wp
Max. input voltage 1000 V
MPP voltage range 250 V to 950 V
Rated input voltage 600 V
Min. input voltage / initial input voltage 350 V
Max. input current per string 90 A
Number of independent MPP inputs / strings per MPP input 3 / 4-4-4

Output (AC)
Rated power (at 230/400 V, 50 Hz) 70000 W
Max. apparent power AC 70000 VA
Nominal AC voltage 220 V / 380 V,230 / 400 V
Nominal AC voltage range 310 V to 480 V
AC grid frequency / range 50 Hz, 60 Hz / −5 Hz to +5 Hz
Max. output current 80A
Power factor at rated power 1
Adjustable displacement power factor 0.8 overexcited to 0.8 underexcited


Efficiency
Efficiency Max. efficiency / Euro-eta 98.6% / 98.4%

Benefits

High-yield

  • Max 98.6% efficiency

  • Real time precise MPPT algorithm for max harvest

  • Wide input voltage operation range from 250V to 960V

All in one.

  • Flexible and economical system solution
  • DC switch

  • DC surge protection device

  • AC surge protection device(option)

  • Built-in PV combiner